Benefits & Sustainability

Comprehensive Power Quality and Energy-Saving Advantages

XL Systems Improve Facility Power Quality (H₂)

The XL mechanism for power factor correction of inductive circuits and loads is the introduction of resultant leading amperage generated by the transformer action of XL chokes from the other phases. 

  • Green lightning bolt symbol on transparent background.

    This amperage enters each phase from the other phases through the particular orientation of XL coil windings in the chokes and reactors.

  • Green lightning bolt symbol on transparent background.

    The amperage generated in XL devices leads the source voltage by 95 degrees, which cannot be achieved by capacitors. XL technology is superior to capacitors for power factor correction because the small, reactive amperage is corrected by more than 90 degrees.

  • Green lightning bolt symbol on transparent background.

    XL systems are passive and do not create RLC resonance; the leading power factor, which is induced every 1/2 cycle, will have no effect on the performance or reliability of motors, equipment, and sensitive machines.

Engineer holding tablet monitoring industrial plant

In practice, an XL 480V 3-Phase Delta module will correct the power factor by injecting a leading amperage of 32 amps into each phase. To maximize I²R savings (power loss in conductors) and load protection, it's best to locate XL modules close to large inductive loads. However, location is not too critical because the small capacitive leading amperage will eventually cancel out inductive amperage somewhere in the electrical system.

See this Power Factor TIS Graph Link to further understand how XL Systems improve power factor by reducing apparent power (KVA), reactive power (KVAR), and current (amps).

Workers reviewing data on a tablet

Superior Spike and Surge Protection

The XL-Series product technology employs patented self-healing magnetic chokes and metal oxide varistors (MOVs) as its two forms of surge and spike protection. The term self-healing, means that most current and voltage transients are reduced via magnetic phase balancing rather than dissipation via MOV components. The immediate benefit to XL customers is continuous protection of connected capital equipment loads and other investments.

A surge is any voltage increase lasting 3 or more nanoseconds. A spike is any voltage increase lasting less than 3 nanoseconds.

XL Surge & Spike Protection Circuitry

XL Systems detect any surge or spike traveling along one of the active phases and shunt it to the other two phases. From there, the transformer/choke sets within each XL module attenuate the surge/spike through the action of the “chokes,” which use capacitors and inductors to resist the change in voltage and associated change in current and flatten out the waveform.

A portion of the surges and spikes are absorbed and converted into "usable power," which is injected back into the electrical system as safe, usable power to be used by downstream loads.

When XL “Wye” modules are specified on Main Distribution Panels (MDP) at service entrance(s), the electrical systems are protected against ground fault transients and/or secondary lightning strike effects, which can enter the facility through neutral conductors.